Grundig Aura User Manual

Page of 37
Abgleichvorschriften / Adjustment Procedures
AURA
8
GRUNDIG Service
Adjustment
Preparation
  Adjustment Procedure
2. Tape Drive
Test equipment: Frequency counter, Test Cassette 448A (Part No. 35079 023 0000)
Tape Speed
Adjustment
Preparation
  Adjustment Procedure
Insert Test Cassette 448A and play 3150Hz part.
Connect a frequency counter to loudspeaker outputs.
With the ´Motorpoti´ adjust for 3150Hz 
±
 100Hz.
Motorpoti
,,
,,
,,
,,
,,
,,
,
,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,
,,
,,
,
,
,
EMK
Rg
50
Ω
Kabel
50
Ω
37.5
Ω
55
Ω
15pF
150
Ω
,,
,,
,,
37.5
Ω
60pF
E´= EMK - 26dB
AM
For adjustment use the aerial dummies for AM resp. FM
,,
,,
,,
,,,
,,,
,
,
,,
,,
,,,
,,,
,,,
,,,
,,,,
,,,,
,,,,
,,,,
,,
,,
,,
,,
,,
,,
EMK
Rg
50
Ω
Kabel
50
Ω
10
Ω
45
Ω
10nF
60
Ω
75
Ω
E´= EMK - 6dB
FM
12. Stereo Crosstalk
13. FM search level
stop
14. Power Amplifier
Over Temperature
Connect a Test Generator via a Stereo Coder to aerial
input; Frequency 95.0MHz; f
mod
 1kHz at 22.5kHz dev.; Pilot
19kHz at 7.5kHz dev.; RDS 57kHz at 1.2kHz dev.; E´ = 1mV
(60dB
µ
V); modulate only the left channel.
Connect an AF Voltmeter to loudspeaker outputs.
Call up the extended expert mode (see above).
Select parameter 53.
Connect a Test Generator to aerial input; Frequency
95.1MHz; no modulation;
Call up the extended expert mode (see above).
Apply a signal with E´ = 80
µ
V (38dB
µ
V). Set DX to OFF.
Apply a signal with E´ = 8
µ
V (18dB
µ
V). Set DX to ON.
In ´cold´ condition measure the voltage U
m
 at FMP1609.
Calculate the parameter value: W = (U
m
 - 340mV) / 16.9mV.
e.g.: U
m
 = 1.20V. W = (1200mV - 340mV) / 16.9mV.
W = 860mV / 16.9mV = 43.8 = 44.
Set the parameter value  for minimum AF voltage on the
right channel
.
Change Parameter value 03 until search just stops.
Change Parameter value 02 until search just stops.
Change Parameter 65 to the calculated value.
e.g.: 
E
 65 44
.
Dolby noise reduction under license from Dolby Laboratories Licensing Corporation.
„DOLBY“ and the double D Symbol 
g
 are trademarks of Dolby Laboratories Licensing Corporation.
NR = Noise Reduction.