13. CHARACTERISTICS 
 
13.2 Power supply equipment capacity and generated loss 
(1) Amount of heat generated by the servo amplifier 
Table 12.1 indicates servo amplifier's power supply capacities and losses generated under rated load. 
For thermal design of an enclosure, use the values in Table 13.1 in consideration for the worst 
operating conditions. The actual amount of generated heat will be intermediate between values at 
rated torque and servo-off according to the duty used during operation. When the servo motor is run at 
less than the maximum speed, the power supply capacity will be smaller than the value in the table, 
but the servo amplifier's generated heat will not change. 
 
Table 13.1 Power supply capacity and generated heat per servo amplifier at rated output 
(Note 2) 
Servo amplifier-generated heat[W] 
Area required for heat dissipation 
Servo amplifier 
Servo motor 
(Note 1) 
Power supply 
capacity[kVA] 
At rated torque 
With servo off 
[m
2
] [ft
2
HC-KFS053 13 0.3 
25 
15 
0.5 
5.4 
HC-MFS053 13 0.3 
25 
15 
0.5 
5.4 
MR-J2S-10CP(1) 
HC-UFS13 0.3  25  15  0.5  5.4 
HC-KFS23 0.5  25  15  0.5  5.4 
HC-MFS23 0.5  25  15  0.5  5.4 
MR-J2S-20CP(1) 
HC-UFS23 0.5  25  15  0.5  5.4 
HC-KFS43 0.9  35  15  0.7  7.5 
HC-MFS43 0.9  35  15  0.7  7.5 
MR-J2S-40CP(1) 
HC-UFS43 0.9  35  15  0.7  7.5 
HC-SFS52 1.0 40  15  0.8 8.6 
HC-SFS53 1.0 40  15  0.8 8.6 
MR-J2S-60CP 
HC-LFS52 1.0 40  15  0.8 8.6 
HC-KFS73 1.3  50  15  1.0 10.8 
HC-MFS73 1.3  50  15  1.0 10.8 
MR-J2S-70CP 
HC-UFS72 73 1.3 
50 
15 
1.0 
10.8 
HC-SFS81 1.5 50  15  1.0 10.8 
HC-SFS102 103 1.7 
50 
15 
1.0 
10.8 
MR-J2S-100CP 
HC-LFS102 1.7  50  15  1.0  10.8 
HC-SFS121 2.1  90  20  1.8  19.4 
HC-SFS201 3.5  90  20  1.8  19.4 
HC-SFS152 153 2.5 
90 
20 
1.8 
19.4 
HC-SFS202 203 3.5 
90 
20 
1.8 
19.4 
HC-RFS103 1.8  50  15  1.0  10.8 
HC-RFS153 2.5  90  20  1.8  19.4 
HC-UFS152 2.5  90  20  1.8  19.4 
MR-J2S-200CP 
HC-LFS152 2.5  90  20  1.8  19.4 
HC-SFS301 4.8  120  20  2.7  29.1 
HC-SFS352 353 5.5 
130 
20 
2.7 
29.1 
HC-RFS203 3.5  90  20  1.8  19.4 
HC-UFS202 3.5  90  20  1.8  19.4 
MR-J2S-350CP  
HC-LFS202 3.5  90  20  1.8  19.4 
HC-SFS502 7.5  195  25  3.9  42.0 
HC-RFS353 5.5  135  25  2.7  29.1 
HC-RFS503 7.5  195  25  3.9  42.0 
HC-UFS352 5.5  195  25  3.9  42.0 
HC-UFS502 7.5  195  25  3.9  42.0 
HC-LFS302 4.5  120  25  2.4  25.8 
MR-J2S-500CP 
HA-LFS502 7.5  195  25  3.9  42.0 
HC-SFS702 10.0  300  25  6.0  64.6 
MR-J2S-700CP 
HA-LFS702 10.6  300  25  6.0  64.6 
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value assumes that the power 
factor improving reactor is not used. 
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the 
regenerative option, Refer to section 14.1.1.