Rockford Fosgate 500.2 User Manual

Page of 42
– 20 –
Level Setting the BLT
• Disconnect Speaker(s) from the amplifier
• CD Software used to set levels is a test tone of 1kHz at “0dB” or “All Bits High”
• Source Unit set to 3/4 volume (or maximum unclipped output)
• Remove BLT Cover to access 
test pads and gain pots
• AC Voltmeter set to 
AC Volts
• AC Voltmeter “–” connected to 
RCA shield of BLT
• AC Voltmeter “+” connected to 
test pad inside the BLT
• Adjust BLT Gain from 
3.25 VRMS min. to 10.3 VRMS max per test pad (see chart below)
Be sure the time index reads greater than 30 seconds on source unit.
*Absence of gain overlap will reduce SPL and may not permit amplifier to reach full output power due to various CD
software.
Gain Overlap
BLT Output (AC Volts)
Performance Characteristics
+0dB*
3.25 VRMS
Best S/N Ratio, Reduced SPL
+5dB
5.8 VRMS
Good S/N Ratio & SPL
+10dB
10.3 VRMS
Best Compromise between S/N Ratio & SPL