Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Features and technical reference 
1200
Call Coverage 
20
Hold
If a user places a call on hold, the display returns to normal mode. The user 
must press disp-chrg again to view call charges, or if automatic charge 
display is enabled, must wait for the display to refresh.
Last Number Dialed
Users can view the dialed number while active on a call by pressing the 
stored-numb button, then the last-numb button. To view call charges again, 
the user must then press the disp-chrg button, or (if Automatic Charge 
Display is part of the user’s COR) the Normal button.
QSIG
In any configuration where a branch system has no direct connection to the 
public network, the private network does not pass call charge information 
to these branches.
System Resets 
If you perform a warm reset while calls are active with charge display, the 
charge display will freeze. To resume call charge updates, users must press 
the Normal button.
Call Coverage
Call Coverage provides automatic redirection of calls to alternate answering 
positions in a Call Coverage path. Call Coverage allows you to:
Establish coverage paths with up to 6 alternate answering positions
Establish redirection criteria that govern when a call redirects 
Redirect calls to a local switch location
Redirect calls to a remote (off-net) location
Redirect calls based on time-of-day
Allow users to change back and forth between two coverage choices (either 
specific lead coverage paths or time-of-day tables). Refer to 
‘‘Extended 
User Administration of Redirected Calls’’ on page 1327
 for more 
information.
Hardware requirement
The Coverage of Calls Redirected Off-Net (CCRON) generally requires call 
classification hardware. Both the Call Classifier - Detector and Tone Clock/Call 
Classifier - Detector circuit packs provide tone detection ports including the 
capability to do call classification. There are 8 ports on each circuit pack.