Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Features and technical reference 
1228
Call Detail Recording 
20
The following information applies to the port used for the secondary CDR output 
device:
Data going to the secondary port should be the same as that going to the 
primary port. You can use the following record types for secondary output: 
LSU, Int-Direct, Int-Process, and Unformatted.
If the system experiences problems in sending records to the primary CDR 
Output Device, the system discontinues sending records to the secondary 
port for 2 minutes. The secondary port should be run at the highest possible 
speed in order to prevent loss of information.
If the output buffer is full, the system busies out the secondary port for 2 
minutes. This makes system resources available to send data to the primary 
CDR port before the data is lost. The system continues to busy out the 
secondary port for 2-minute intervals until less than 400 records (1800 for 
Release 5r and later) remain in the buffer.
CDR Record formats
Two types of formats are sent to the CDR output device, date record and call detail 
formats.
Date record format
CDR sends date information to the CDR device once a day (at midnight), or when 
the device is connected. This is a non-call record, and contains only the 
information shown in the date record formats below.
Several formats are available for date records: one for CDRUs, one for the printer, 
and one for the TELESEER. The records sent to the TELESEER and printer 
contain the date only while the records sent to the CDRU contain time. See 
Table 
24
Table 25
, and 
Table 26
.
NOTE:
The date can be in month/day or day/month format, as selected on the CDR 
System Parameters form. The date/time may also be reversed for 
international standards.
Table 24.
Date Record Format to LSU, LSU-Expand, Unformatted, and 
Customized
 Position
Data Field Description
1–2
Hour (leading 0 added if needed)
3
Colon (:)
4–5
Minute (leading 0 added if needed)