Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Managing multimedia calling 
248
Multimedia Call Handling 
9
11. Set the CRC
 
field to 
y
12. The Idle Code default is 11111111.
13. The DCP/Analog Bearer Capability default is 3.1 kHz.
14. Set the 
M
MI Cabling Board
 
field to
 
xxxxx 
(where xxxxx is the location of 
the TN787 MMI circuit pack recorded in step 2). This must be the slot for 
port B of the Y-cable.
15.
The 
MMI Interface
 
field
 
ESM 
appears.
Signaling-Group form, page 1
Screen 18.
Signaling-Group Form (Page 1 of 5)
1. Enter 
add signaling-group next
 and the signaling-group form appears.
2. Change 
A
ssociated Signaling field to 
y
.
3. Change Primary D-Channel Port field to
 xxxx16
 (where xxxx is the 
address of the TN2207 PRI circuit pack, for example: 1B0516).
4. The Max Number of NCA TSC default is 
0.
5. The Max Number of GA TSC default is 
0.
6. Trunk Group for NCA TSC ____ (leave blank)
7. Trunk Group for Channel Selection____ (leave blank)
8. Logoff the terminal and then log back on the terminal to view your 
changes.
Troubleshooting. 
To determine ESM link status enter the following commands 
from the system administration terminal:
1. Status esm
2. Status signaling-group
3. List MMI
change signaling-group 6                                        Page   1 of   5
                                SIGNALING GROUP
 
 Group Number: 6
                    Associated Signaling? y          Max number of NCA TSC: 0
                       Primary D-Channel: 01C0916     Max number of CA TSC: 0
                                                   Trunk Group for NCA TSC:
       Trunk Group for Channel Selection:
          Supplementary Service Protocol: a