Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
System basics 
14
Saving translations 
1
end of the specified grace period, otherwise you cannot access system 
management commands (such as: add, change, remove, and duplicate) that 
modify translation data. Lucent specifies the grace period during a system 
installation or following an upgrade.
Before you start
If you are saving translations to a memory card or tape, you must verify the 
memory card or tape is in place and clear any active alarms from the alarms panel. 
If your switch is a G3csi or G3si, verify the memory card translation ID matches 
the translation ID of your switch’s Flash PROM.
Instructions
In our example, we save translations to the tapes on both processor A and B.
To save translations manually:
1. Type 
save translation both tape 
and press 
RETURN
.
The save process can take up to 10 minutes. You cannot administer your 
system while the save is in process. The Save Translation screen appears.
2. If there is an error message in the Command Completion Status field and 
an error code in the Error Code field, clear the error and repeat the save 
process.
More information
When mass storage system (MSS) devices on both processors in a duplex system 
are specified, translation data is saved from the active processor to the active and 
standby MSS devices at the same time. If the save to one device fails or one device 
is out of service, the other save continues. You receive the status of each save 
separately.
NOTE:
If you have a duplex system and you save translation data to both MSS 
devices one at a time, translation data inconsistencies between the two 
devices can occur.
SAVE TRANSLATION
Processor
Command Completion Status
Error Code
SPE_A
Success
0
SPE_B
Success
0