Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Introduction to the DEFINITY system 
21
Adding feature access codes 
2
Adding extension ranges
You may find that as your needs grow you want a new set of extensions. Before 
you can assign a station to an extension, the extension must belong to a range that 
is defined in the dial plan. Let’s add a new set of extensions that start with 3 and 
are 4 digits long (3000–3999).
To add this set of extensions to the dial plan:
1. Type 
change dialplan
 and press 
RETURN
.
The 
Dial Plan Record
 screen appears.
2. Move the cursor to the 3rd row in the 4th column.
3. Type 
extension
 in the selected field.
4. Press 
ENTER
 to save your changes.
Other options for the dial plan
You can establish a dial plan so that users only need to dial one digit to reach 
another extension. You can also establish a dial plan that allows users to dial, for 
example, three digits to reach one extension, and four digits to reach another. This 
is particularly useful in the hospitality industry, where you want users to be able to 
simply dial a room number to reach another guest. For more information, see 
‘‘Single-Digit Dialing and Mixed Station Numbering’’ on page 1487
Adding feature access codes
As your needs change, you may want to add a new set of feature access codes for 
your system. Before you can assign a FAC on the Feature Access Code screen, it 
must conform to your dial plan.
In our example, if you want to assign a feature access code of 33 to Last Number 
Dialed, first you need to add a new FAC range to the dial plan.
To add a FAC range from 30–39:
1. Type
 change dialplan
 and press 
RETURN
.
The Dial Plan Record screen appears.
2. Move the cursor to the 3rd row and the 2nd column.
3. Type 
fac
 in the selected field.
4. Press 
ENTER
 to save your changes.