Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
468
Access Endpoint 
17
Extension
A display-only field showing the extension number as specified in the command 
line, or shows the next available extension number if 
next
 was entered on the 
command line. This is the extension number assigned to the nonsignaling trunk 
and used to access the trunk endpoint.
(Starting) Port
Enter seven characters.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number 
(port) 12.
NOTE:
For Wideband Access Endpoints, analog tie trunks cannot be used and the 
DS1 Interface circuit pack, Version C or later, must be used.
The DS1 circuit number corresponds to the channel that will carry the data traffic. 
Channels 1 through 31 (DS1 Interface only) or channels 1 through 24 (DS1 Tie  
Trunk, DS1 Interface, or DS1 Interface (32)  circuit packs) may be used when the 
DS1 Signaling Type field is 
robbed-bit
 or 
isdn-ext
. For Common Channel or 
ISDN-PRI signaling, channel use is limited to channels 1 through 30 (DS1 
Interface  circuit pack only) or channels 1 through 23 (DS1 Interface (32)  or DS1 
Interface ). A channel can be administered as an access endpoint regardless of the 
DS1 signaling type.
Valid entries
Usage
01
 through 
44
 (G3r) or
01
 through 
03
 (G3si)
First and second characters are the cabinet number
A
 through 
E
Third character is the carrier
01
 through 
20
Fourth and fifth character are the slot number
01
 through 
04
 
(Analog TIE trunks)
01
 through 
31
 
(DS1 Interface ports)
Six and seventh characters are the circuit number