Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
476
Alias Station 
17
Alarm Threshold
Only appears if an entry in the Alarm Type field is other than 
none
. Enter the 
number of times an attempt to establish or reestablish an AC must fail 
consecutively before an AC alarm generates. (an alarm will be generated after the 
fourth retry has failed, thus, with the retry interval of 2 minutes, an alarm will be 
generated approximately 8 minutes after the first failure occurs).
Retry Interval
Auto Restoration
Priority
Enter a number that is to be used to determine the order in which ACs are to be 
established.
Alias Station
This screen allows you to configure the system so that you can administer new 
phone types that are not supported by your system software. This screen maps 
new telephone models to a supported telephone model. This mapping does not 
guarantee compatibility, but allows nonsupported models to be administered and 
tracked by their own names.
Valid entries
Usage
1
 through 
10
An alarm generates on the first failure if this field is 
1
.
Valid entries
Usage
1
 through 
60
Enter the number of minutes between attempts to establish or 
reestablish the AC
Valid entries
Usage
 
y
Enter 
y
 to indicate an attempt is to be made to reestablish an 
AC that failed. Auto Restoration is available only for an AC 
that is established over an ISDN Software Defined Data 
Network (SDDN) trunk group. A 
y
 in this field is ignored in all 
other situations.
Valid entries
Usage
1
 through 
8