561
Data modules 
17
data-line
Assigns a Data Line Data Module. The Data Line Data Module 
(DLDM) screen assigns ports on the Data Line circuit pack 
(DLC) that allows EIA 232C devices to connect to the system. 
The DLC, with a companion Asynchronous Data Unit (ADU), 
provides a less expensive data interface to the system than 
other asynchronous DCP data modules.
The DLC supports asynchronous transmissions at speeds of 
Low and 300, 1200, 2400, 4800, 9600, and 19200 bps over 
2-pair (full-duplex) lines. These lines can have different 
lengths, depending on the transmission speed and wire gauge.
The DLC has 8 ports. The connection from the port to the EIA 
device is direct, meaning that no multiplexing is involved. A 
single port of the DLC is equivalent in functionality to a data 
module and a digital line port. The DLC appears as a data 
module to the Digital Terminal Equipment (DTE) and as a 
digital line port to the switch.
The DLC connects the following EIA 232C equipment to the 
system:
Printers
Non-Intelligent Data Terminals
Intelligent Terminals, Personal Computers (PCs)
Host Computers
Information Systems Network (ISN), RS-232C Local 
Area Networks (LANs), or other data switches.
ethernet
Assigns an Ethernet data module. The Ethernet Data Module 
screen assigns the 10BaseT port on the Control-LAN (C-Lan) 
circuit pack. This port provides a TCP/IP connection to 
network hub or LAN. Refer to DEFINITY ECS Administration 
for Network Connectivity
 for more information on Ethernet 
data modules.
Valid entries
Usage