575
Data modules 
17
Default Data Applications
Used with 7500 and World Class BRI Data Modules. Used to identify mode to be 
Used with originating data calls when the mode is not specified with the calling 
parameters. This mode is also used for terminating trunk calls that do not have 
bearer capability specified or administered connections. Refer to 
‘‘Generalized 
route selection’’ on page 1340
 for additional information.
MM Complex Voice Ext:
Used with 7500 and World Class BRI Data Modules. This display-only field 
contains the number of the associated phone in the multimedia complex. It only 
appears when the Multimedia field is 
y
. This field is left blank until you enter the 
data module extension in MM Complex Data Ext field on the Station screen. Once 
you complete the field on the Station screen, these two extensions are associated 
as two parts of a one-number complex, which is the extension of the phone. Valid 
values conform to your dial plan.
Field descriptions for page 2
Screen 65.
Data Line Data Module — if KYBD Dialing is y
Valid entries
Usage
M0
Mode 0. Use this setting for a WCBRI endpoint used as an 
administered connection.
M1
Mode 1
M2_A
Mode 2 asynchronous
M2_S
Mode 2 synchronous
M3/2
Mode 3/2 adaptable
blank
change data-module 30                 DATA MODULE                Page 2 of 2
        CAPABILITIES
                       KYBD Dialing? y                    Configuration? n
                           Busy Out? n
        SPEEDS
              Low? y           1200? y           4800? y          19200? y
              300? y           2400? y           9600? y     Autoadjust? n
        OPTIONS
                    Permit Mismatch? n                     Dial Echoing? y
                Disconnect Sequence: two-breaks             Answer Text? y
                             Parity: even          Connected Indication? y