Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
670
Feature-Related System Parameters 
17
Date Format on 6400/8400 Terminals
The format of the date as displayed on the telephones.
On-hook Dialing on 6400/8400 Terminals
For 6400/8400 telephone users with speakerphones.
The next four fields control station-to-switch recall signal timing. If a flashhook 
interval (recall window) is required, the upper and lower bounds of the interval 
can be administered. An on-hook that lasts for a period of time greater than or 
equal to the lower bound and less than or equal to the upper bound will be treated 
as a recall flash. If an interval is not required, the Disconnect Timing value must 
be administered. An on-hook that lasts for a period of time less than this value will 
be ignored; greater than or equal to this value will be regarded as a disconnect. 
Regardless, an on-hook lasting 50 to 150 ms coming from a 2500-type set will 
always be treated as a digit pulse unless Ignore Rotary Digits is 
y
 for that station.
Flashhook Interval
Valid entries
Usage
mm/dd/yy 
month/day/year
dd/mm/yy
day/month/year
yy/mm/dd
year/month/day
Valid entries
Usage
y/n
 Enter 
y
 allows users to dial without lifting the handset. If you 
enable this, users hear dial tone when they press the Speaker 
button, even if the handset is on-hook.
Valid entries
Usage
Enter 
y
 to indicate that a flashhook interval (recall window) is 
required. If a 
y
 is entered, Upper Bound and Lower Bound 
appear
n
If 
n
 is entered, Disconnect Timing appears.