Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
679
Feature-Related System Parameters 
17
BCMS/VuStats Measurement Interval
You can enter 
half-hour
 or 
hour
 for polling and reporting measurement data if the 
BCMS (Basic) and/or the VuStats on the System-Parameters Customer-Options 
screen is 
y
.
BCMS/VuStats Abandon Call Timer (seconds)
Specifies the number of seconds before calls are considered abandoned. Calls with 
talk time that is less than this number (and that are not held) are tracked by BCMS 
and displayed by VuStats as ABAND calls.
Validate BCMS/VuStats Login IDs
Clear VuStats Shift Data
Valid entries
Usage
half-hour
 
There are a maximum of 25 time slots available for 
measurement intervals. If 
hour
 is specified, an entire day of 
traffic information will be available for history reports; 
otherwise, only half a day will be available. This does not 
affect daily summaries as they always reflect traffic 
information for the entire day. The interval may be changed at 
any time, but will not go into effect until the current interval 
completes.
hour
 
Valid entries
Usage
1
10
 
Valid entries
Usage
y
Enter 
y
 to allow entry only of login-IDs that have been entered 
on the BCMS Login-ID screen.
n
  
Enter 
n
 to allow entry of any ACD login of the proper length.
Valid entries
Usage
on-login
 Enter 
on-login
 to clear shift data for an agent when the agent 
logs in.
at-midnight
Enter 
at-midnight
 to clear shift data for all agents at midnight.