Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
727
IP Trunk Configuration Manager 
17
The Telephony property page contains the following parameters:
Parameter
Description
Telephony Board 
Installed
These display-only fields show:
Number of Boards: 1
Type of Board: IP Trunk
Trunk Control Protocol: IP Trunk - T1
IP Trunk - E1
DSP Resources 
Installed
Number of Boards: Identifies the number of DSP cards installed 
in the server.
Type of Board: Identifies the type of DSP cards installed in the 
server. In this release, only the TAP-802 DSP card is supported. 
This information is display-only.
Ports
Port Number: Allows you to specify the ports that you want to 
enable or disable by entering the port number, and selecting the 
Enable or Disable option button in the Status control group.
The maximum number of ports available is limited to the number 
of DEFINITY ECS licenses you purchased.
By default, all ports from 1 to the maximum number are set to an 
active state (even if this exceeds the number of licenses you 
purchased). 
Show All Ports: Displays a list of available ports in the 
telephony subsystem.
If a port is a member of a line pool (refer to the QoS tab), a # sign 
appears next to its number in the list of all ports (even if the line 
pool is in an “idle” or “monitor only” mode).
If a port is disabled, an asterisk (*) appears next to its number in 
the list of all ports.
Continued on next page