Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
808
Login Administration 
17
Screen 159.
Access Security Gateway Login Administration
Blocked
Setting the Blocked field to y does not remove the login ID from the system.
System Generated Secret Key
Secret Key
The value of this field is only displayed during the initial add or change login 
command to allow it to be programmed into any ASG Site Manager, ASG Mobile, 
or ASG Pass-Key used to interact with ASG for user authentication. 
If the System Generated Secret Key field is set to y, the system generates the 
secret key. If the System Generated Secret Key field is set to n, the administrator is 
required to enter a 20-digit octal value. It is important to note the value of the 
secret key so you can enter it into response generation devices.
Valid entries
Usage
y/n
Enter 
y
 to temporarily disable the login ID from accessing the 
system through the ASG interface.
Valid entries
Usage
y/n
Enter 
y
 to generate the secret key by the system and display it to 
the administrator.
add login
Page 2 of 2
ACCESS SECURITY GATEWAY LOGIN ADMINISTRATION
Blocked?: n
System Generated Secret Key?: n
Secret Key: ____________________
EXPIRATION CRITERIA
Expiration Date: __/__/____
Number of Sessions: __
RESTRICTION CRITERIA
Restrict Days of Week
Monday? n
Tuesday? n 
Wednesday? n 
Thursday? n 
Friday? n
Saturday? n 
Sunday? n
Restrict From Time: __:__