Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
817
Modem Pool Group 
17
Modem Pool Group
There are two types of conversion resources for Modem Pooling. The first type, an 
integrated conversion resource, is a circuit pack that emulates a Trunk Data 
Module connected to a 212A-type modem. Two conversion resources are on each 
circuit pack.
The second type, a combined conversion resource, is a separate Trunk Data 
Module and modem administered as a unit. The Trunk Data Module component of 
the conversion resource may be either a Modular Trunk Data Module (MTDM) or 
7400A Data Module and connects to a digital port using Digital Communications 
Protocol (DCP); the modem connects to an analog port.
Field descriptions for page 1
Screen 162.
Modem Pool Group — Integrated screen if Group Type is integrated
change modem-pool num                                                  Page 1 of 1
                                   MODEM POOL GROUP
Group Number: 1 
            Group Type: integrated
Receiver Responds to Remote Loop? n 
  Hold Time (min): 5
Send Space Disconnect? y
  Receive Space Disconnect? y
CF-CB Common? y   Loss of Carrier Disconnect? y
Speed: LOW/300/1200    
Duplex: full     Synchronization: a/sync
CIRCUIT PACK ASSIGNMENTS
               Circuit Pack   Circuit Pack
               Location       Location
               1: ___         9: ___
               2: ___        10: ___
               3: ___        11: ___
               4: ___        12: ___
               5: ___        13: ___
               6: ___        14: ___
               7: ___        15: ___
               8: ___        16: ___