Screen reference 
849
Personal CO Line Group 
17
Screen 171.
Personal CO Line Group
The following fields are unique to this screen.
Analog Loss Group
This field determines which administered 2-party row in the loss plan applies to 
this trunk group if the call is carried over an analog signaling port in the trunk 
group. 
Coverage Path
Valid entries
Usage
1
 to 
17
Shows the values from the loss plan and tone plan.
Valid entries
Usage
1
 to 
999
Enter the number of the call coverage path you want to use for 
incoming calls.
t1
 to 
t999
Enter the number of a time-of-day table.
blank
Assigning a coverage path is optional: leave this field blank if 
you do not want to assign one.
add personal-CO-line
Page 1 of x
                            PERSONAL CO LINE GROUP
 Group Number: __
Group Type:_____________
CDR Reports: _
   Group Name: _________________
 
TAC: ____
Security Code: ____ 
Coverage Path: ____
Data Restriction? _
Outgoing Display? _
TRUNK PARAMETERS
Trunk Type: _____________
Trunk Direction: ________
Trunk Port: _______
Disconnect Timing(msec): ____
Trunk Name: __________ 
Trunk Termination: ______
Outgoing Dial Type: _________
Analog Loss Group: ___
Prefix-1? _
Digital Loss Group: ___
Disconnect Supervision - In? _
Call Still Held? _
Answer Supervision Timeout: ___ 
Receive Answer Supervision? _
Trunk Gain: ____ 
Country: __
Charge Conversion: _____
Decimal Point: ______
Currency Symbol: ___
Charge Type: _______