Lucent Technologies 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
861
Remote Access 
17
Authorization Code Required
When you use an authorization code in conjunction with a barrier codes it 
increases the security of the Remote Access feature.
Remote Access Dial Tone
Set this field to 
n
 for maximum security. This field appears when the 
Authorization Code Required field is set to y.
Barrier Code
You must assign a barrier code that conforms to the number entered in the Barrier 
Code Length field. You may enter up to 10 barrier codes per system. Duplicate 
entries are not allowed. You must keep your own records regarding the 
distribution of these barrier codes to your personnel.
COR
Assign the most restrictive class of restriction (COR), that provides only the level 
of service required, to provide the maximum security.
Valid entries Usage
y/n
Enter 
y
 to require an authorization code be dialed by Remote 
Access users to access the system’s Remote Access facilities.
Valid entries
Usage
y/n
Enter 
n
 so that there is no Remote Access Dial Tone prompt.
Valid entries
Usage
to 
9
Enter a 4- to 7-digit number in any combination of digits.
none
Must be specified in the first Barrier Code field, if the Barrier 
Code Length field is blank.
Valid entries
Usage
through
 95
Enter the COR number associated with the barrier code that 
defines the call restriction features.