TP-LINK TL-SC3430 User Manual

Page of 92
 
 
71
 
¾
 
Threshold: It means the extent which the alarm will be triggered. The default value is 50 and 
the value range is 0~100. The larger the value, the higher the threshold. 
¾
 
Sensitivity:  It means that how often the sensor will scan the image different. The higher 
sensitivity it is and the more frequently it scans. The default value is 50 and the value range is 
0~100. The larger the value, the higher the sensitivity. 
z
 
Motion Detection 1: Click it on for using Motion Detection 1 function as a sensor. You can 
adjust and move the detecting zone by using mouse.   
z
 
Motion Detection 2: Click it on for using Motion Detection 2 function as a sensor. You can 
adjust and move the detecting zone by using mouse.   
z
 
Motion Detection 3: Click it on for using Motion Detection 3 function as a sensor. You can 
adjust and move the detecting zone by using mouse. 
8.7 Audio Detection 
The  Audio detection has Threshold and Sensitivity inputs which you can adjust sequentially. Audio 
Detection function can support to FTP Client, SMTP, Network Storage, and HTTP Event