Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-389
CLAN-BD (Control LAN Circuit Pack)
9
Error Log Entries and Test to Clear Values
Table 9-162.
CLAN-BD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)
0
MINOR
ON
18 (b)
WARNING
OFF
release board UUCSS
217 (c)
0
None
WARNING
ON
257
65535
Control Channel
Loop Test (#52)
Loop Test (#52)
MINOR
ON
test board UUCSS l r 20
257 (d)
513 (e)
4352-
4357
4357
MINOR
ON
769 (f)
4358
1291 to
1296 (g)
1296 (g)
MINOR
ON
reset board UUCSS
1537(h)
Any
MINOR
ON
1793-
1795 (i)
1795 (i)
MINOR
ON
2049 (j)
Packet Interface
Test (#598)
Test (#598)
MINOR
ON
test board UUCSS l r 3
2305
2306 (k)
2306 (k)
2561 to
2668 (l)
2668 (l)
Any
Socket Error
2817
2819 (m)
2819 (m)
Congestion Query
Test (#600)
Test (#600)
MINOR
ON
test board UUCSS s r 3
3073 (n)
PPP Link Status
Inquiry Test (#1279)
Inquiry Test (#1279)
MINOR
ON
test board UUCSS s
3330 (o)
MINOR
ON
reset board UUCSS
3586 (p)
3840 (q)
4096-
4100
4100
3841
3843 (r)
3843 (r)
Continued on next page