Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-389
CLAN-BD (Control LAN Circuit Pack) 
9
Error Log Entries and Test to Clear Values
Table 9-162.
CLAN-BD Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1(a)
0
MINOR
ON
18 (b)
WARNING
OFF
release board UUCSS
217 (c)
0
None
WARNING
ON
257
65535
Control Channel 
Loop Test (#52)
MINOR
ON
test board UUCSS l r 20
257 (d)
513 (e)
4352- 
4357
MINOR
ON
769 (f)
4358
1291 to 
1296 (g)
MINOR
ON
reset board UUCSS
1537(h)
Any
MINOR
ON
1793- 
1795 (i)
MINOR
ON
2049 (j)
Packet Interface 
Test (#598)
MINOR
ON
test board UUCSS l r 3
2305 
2306 (k)
2561 to 
2668 (l)
Any
Socket Error
2817 
2819 (m)
Congestion Query 
Test (#600)
MINOR
ON
test board UUCSS s r 3
3073 (n)
PPP Link Status 
Inquiry Test (#1279)
MINOR
ON
test board UUCSS s
3330 (o)
MINOR
ON
reset board UUCSS
3586 (p)
3840 (q)
4096- 
4100
3841 
3843 (r)
Continued on next page