DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Management Terminal 
3-25
Connecting the MT 
3
active SPE, connect an M25B (EIA) cord to the connector labeled ACTIVE. 
Connect the other end to the connector on the 715 BCS labeled P2(DCE). 
On most other terminals, use the connector labeled MAIN PORT. A null 
modem is not required for these ports. More information on setting up the 
715 BCS is given in following sections of this chapter.
On systems with duplicated SPEs, there are two PPN control carrier and 
two identical sets of connectors. Either connector labeled ACTIVE can be 
used, regardless of which SPE is active. The STANDBY connectors are 
described below.
SYSAM-RMT Port (RAP)
One login can access the system by dialing in to the SYSAM-RMT port 
with a modem operating at either 1.2 or 2.4 kbps. This port is reserved for 
INADS (Initialization and Administration System) access.
Logging In When The SPE Is In SPE Down Mode
If the system is in SPE down mode when the RAP Terminal displays 
login
, enter 
INADS as the RAP login/name. Use the first INADS type password as your RAP 
password.
NOTE:
You must identify the first INADS login before the system is in SPE 
down mode. The first INADS type login may be identified by entering 
the list login command and noting the first INADS login listed. 
System Ports
 Terminals can log in via system ports (also known as system access ports 
or SAPs) if the system is so equipped. The connection is made by dialing 
in to a to a data port located on a data line circuit pack that is 
administered as a system port. This type of port is identified by the entry 
Type: system port
 on the data module form. These ports operate at 
9.6 kbps. For more information on system ports, see 
Data Line Port)’’
 in 
Chapter 9, ‘‘Maintenance Object Repair Procedures’’
 
and 
DEFINITY Enterprise Communication Server Administrator’s Guide.
EPN Maintenance Circuit Pack
Terminals can log in to the system by directly connecting to the TN775 
Maintenance circuit pack in each Expansion Port Network. Connect an 
M25B (EIA) cord to the RS-232 connector labeled TERM on the rear panel 
of the expansion control carrier. This connection operates at a slower 
speed because it communicates over system control links shared with call 
processing messages. The bit rate is limited to about 1 kbps. This type of 
connection is useful for performing maintenance on a remotely located 
EPN.