DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-468
DC-POWER (Single Carrier Cabinet Environment) 
9
Hardware Error Log Entries and Test to Clear 
Values
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the following table when 
inspecting errors in the system. By clearing error codes associated with the 
Single Carrier Cabinet Power Query Test, for example, you may also clear errors 
generated from other tests in the testing sequence. Test description(s) and 
recommended maintenance procedures follow for all errors that can occur 
during system technician-demanded testing.
Notes:
a. Refer to EMG-XFER (Emergency Transfer) Maintenance documentation for 
a description of this test.
b. Refer to EXT-DEV (External Alarm Lead) Maintenance documentation for a 
description of this test.
c. Refer to RING-GEN (Analog Ring Generator) Maintenance documentation 
for a description of this test.
Single Carrier Cabinet Power Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1
1.
UU is the universal cabinet number indicated in the PORT field of the Alarm Log.
0
2
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU
513
0 or 1
Single Carrier Cabinet 
Power Query (#79) 
MAJOR
ON
test environment UU r 2
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Single Carrier Cabinet Power Query Test (#79)
X
X
ND
Emergency Transfer Query Test (#124) (a)
X
X
ND
External Alarm Lead Query Test (#120) (b)
X
X
ND
Analog Ring Generator Initialization Test (#117) (c)
X
X
ND
Analog Ring Generator Query Test (#118) (c)
X
X
ND