June 1999
Maintenance Object Repair Procedures 
9-487
DID-TRK (Direct Inward Dial Trunk) 
9
m. Incomplete Dial timer expired. This error only applies to the TN459 and 
indicates a problem with incoming dialing stream. Refer the problem to the 
CO.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
NPE Crosstalk Test for example, you may also 
clear errors generated from subsequent tests in the testing sequence..
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected 
time slot on the TDM bus and never crosses over to time slots reserved for other 
connections. If the NPE is not working correctly, one-way and noisy connections 
may be observed. This test is usually only part of a port’s Long Test Sequence 
and takes about 20 to 30 seconds to complete. 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
X
ND
Port Diagnostic Test (#35)
X
X
ND
Looparound and Conference Circuit Test (#33)
X
ND
Port Audit Update Test (#36)
X
X
ND
Table 9-200.
TEST #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources for this test. This could be 
due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page