Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-497
DIG-LINE (Digital Line) 
9
DIG-LINE (Digital Line)
DIG-LINE maintenance monitors and tests ports on digital line circuit packs and 
the hardware connected to those ports for lines administered as a digital station. 
These include stations with just a digital voice terminal and stations with a digital 
voice terminal and a linked data module. Stand-alone data modules, and data 
adaptors in stand-alone mode, are covered by the PDMODULE and TDMODULE 
maintenance objects. Circuit pack-level maintenance is covered by “DIG-BD” 
whose strategy is described in the "XXX-BD (Common Port Circuit Pack)" section. 
Only the TN754B or TN2136 should be used in out-of-building applications. For 
important information pertaining to protection required for out-of-building digital 
voice terminals, see 
DEFINITY Enterprise Communications Server Release 5.4 
Installation and Test for Multi-Carrier Cabinets.
Only 2-wire Italtel Digital Telephone Models 1 and 2 (IDT1/2) or DAs can directly 
connect to a TN2136. Lucent DCP (4-wire) digital voice terminals and data 
modules can connect to these circuit packs via Italtel’s 2/4-wire adapter. DAs 
can operate in either of two modes which are covered by different MOs:
Digital line maintenance interacts with digital line circuit pack (DIG-BD) 
maintenance, and results of DIG-LINE testing can be affected by the health of the 
digital line circuit pack. Keep this in mind when investigating digital line 
problems.
There are instances where the service state of a station is mentioned. It is helpful 
to understand what is meant by the different service states that may exist. The 
different service states which apply to digital line station are explained as follows: 
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
pp is the two digit port number (01, 02, ...).
Full Name of MO
DIG-LINE
MINOR
test port 
UUCSSpp l
Digital Line
DIG-LINE
WARNING
test port 
UUCSSpp sh
Digital Line
DA Mode
Administered as:
Endpoint
MO
Stand-alone
PDM
Data endpoint only
PDMODULE
Linked
DTDM
IDT1/2 and optional data terminal
DIG-LINE