Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-505
DIG-LINE (Digital Line) 
9
j. This is the code that is generated when the link between the circuit pack 
and the voice terminal is successfully reset. No craft action is necessary.
k. No terminal is connected to the Digital Line board. No maintenance action 
is required.
l. An uplink message has been logged indicating that the Electric Power 
Feed (EPF) is on with no load on it. No action is necessary.
m. The circuit pack’s message buffer is full. This may be caused by having 
many display phones with heavy traffic connected to the circuit pack. No 
action is necessary.
n. Internal system error. No action is necessary.
o. There is a problem with the voice terminal EEPROM. When the voice 
terminal is repaired the alarm will be resolved with the passing of time.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Voice and Control Channel Local Looparound 
Test, for example, you may also clear errors generated from other tests in the 
testing sequence.
Digital Terminal Remote Looparound Test (#1201)
This test checks the connection between the SPE and the digital terminal and the 
ability of the terminal and the associated port to send and receive data. This test 
is based on procedure 622 to isolate digital terminal problems.
A request is presented to the terminal to go into loopback mode. Data is sent to 
the terminal and when received back, checked for consistency. This test is run as 
a part of the "test long" procedure. It is not included in any error recovery strategy 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Digital Terminal Remote Looparound Test (#1201) 
X
D
Voice and Control Channel Local Looparound Test (#13)
X
ND
Digital Line NPE Crosstalk Test (#9)
X
ND
Digital Line Electronic Power Feed Test (#11)
X
ND
DIG-LINE Station Lamp Updates Test (#16)
X
X
ND
Station (Digital) Audits Test (#17)
X
X
ND