DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-636
DS1-FAC (DS1 Facility) 
9
DS1-FAC (DS1 Facility)
The DS1-FAC is a part of the DS1 Converter (DS1 CONV) Complex. The DS1 
CONV Complex consists of two TN574 DS1 CONV circuit packs or two TN1654 
DS1 CONV circuit packs connected by one to four DS1 facilities. The 
maintenance object name for the DS1 CONV circuit pack is DS1C-BD, and the 
maintenance object name for the connected DS1 facilities is DS1-FAC.
The TN1654 DS1 Converter Circuit pack is a redesign of the TN574 DS1 
Converter board. The TN1654 provides functionality equivalent to the TN574 but 
also adds a 32-Channel E1 interface for international support as well as 
circuit-switched wideband connections (NxDS0).
The TN1654 DS1 CONV circuit pack is not compatible with the TN574 DS1 
CONV board or the Y-cable used to interface to the TN574 DS1 CONV. A 
TN573B or later suffix SNI board must also be used when connecting to the 
TN1654 DS1 CONV board. See section DS1C-BD for information on both DS1 
CONV circuit packs.
The DS1 CONV Complex is a part of the Port Network Connectivity (PNC). The 
DS1 CONV Complex is used to extend the range of the 32 Mbps fiber links that 
connect EPNs to either the PPN or the Center Stage Switch, allowing EPNs to be 
located at remote sites.
The DS1 CONV circuit pack contains on-board firmware that detects DS1 facility 
alarms and errors, communicates status to maintenance software, and runs tests 
in the background or on demand from maintenance software. The overall 
maintenance software strategy includes demand tests, recovery strategies, error 
logging and alarm logging, and periodic audits.
Every error condition reported by the firmware is associated with the background 
tests that the firmware runs autonomously. Demand tests that are executed by 
the maintenance software do not have any functionality that would effect any 
additional error manipulation by the firmware. However, the Failure Audit test 
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2-44 for EPNs). C is the carrier designation (A, 
B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). f is the 
DS1 facility (a, b, c, or d). See Chapter 7, or the DS1C-BD section, for identification of DS1 
facility LEDs.
Full Name of MO
DS1-FAC
MAJOR
test board UUCSS sh r 1
DS1 Facility
DS1-FAC
MINOR
test board UUCSS sh r 1
DS1 Facility
DS1-FAC
WARNING
test board UUCSS sh r 1
DS1 Facility