Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Initialization and Recovery 
4-16
SPE-Down Command Interface 
4
Bringing the SPE Back into Service
!
WARNING:
In a system with duplicated SPEs, a spontaneous SPE interchange may 
occur if the active SPE is not in good health and either
— an unlocked SPE completes its reboot and handshake is 
reestablished
— a locked SPE in which the Standby Maintenance Monitor (SMM) is 
running is unlocked
!
WARNING:
Use the status spe command to determine the health of the active SPE and 
whether an interchange will occur.
Once all tests pass using the SPE-down interface, the SPE should be competent 
to return to service. There are however certain problems which will not show up in 
testing that may prevent this. Follow the appropriate procedure below to bring 
the SPE back up.
Simplex SPE
After the reboot command is entered, a series of diagnostics is run on the SPE. 
Results are displayed as they occur, as described in preceding sections. If all 
tests pass, the boot image is loaded and control is given to the operating system.
If you cannot get the SPE to reboot after replacing the components that failed 
SPE-down interface tests, follow normal escalation procedures.
Duplicated SPE
The physical connection of the terminal to the STANDBY connector, while the 
SPE is locked standby with the SPE-Select switches, prevents the Standby 
Maintenance Monitor (SMM) from running. Thus, any reboot command to the 
standby while in this state will abort. To reboot an SPE that is locked standby and 
has a terminal connected to it, simply move the SPE-SELECT switches to the 
AUTO position one at a time. This will automatically cause the standby SPE to 
reboot and its progress is displayed on the terminal. Moving the switches back to 
the locked position will cause the reboot to abort.
To reboot the standby SPE and have it remain locked standby following the 
reboot, use the following procedure:
1. Start the reboot by moving the SPE-Select switches one at a time to the 
AUTO position.