Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-663
DS1 CONV-BD 
9
Figure 9-34. DS1 CONV Complex in Duplicated PNC with 1 SN
DS1 CONV Administration and Board Insertion
Board insertion is the detection of a circuit pack by the system. The DS1 CONV 
circuit pack will not be inserted unless the circuit pack type, TN574 or TN1654, is 
entered into the associated field in circuit pack administration screen. The Fiber 
Endpoint (the EI or the SNI) must also be inserted and be operational for the DS1 
CONV circuit pack to function.
Fiber link administration must be completed before the DS1 CONV maintenance 
can be operational. Fiber links are administered via the add fiber-link command. 
Fiber Endpoints, DS1 CONV circuit pack locations and DS1 facility options are 
entered as a part of the fiber link administration.