Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-5
Reseating and Replacing Circuit Packs 
5
Reseating and Replacing Circuit Packs
Most repair procedures involve replacing faulted circuit packs. In some cases, 
problems are resolved by reseating the existing circuit pack. Reseat a circuit 
pack 
only when explicitly instructed to do so by the documented procedures. 
Reseating is discouraged since it can put a faulty component back into service 
without addressing the cause, resulting in additional and unnecessary 
dispatches. After reseating a circuit pack, make sure the problem is really fixed 
by thorough testing and observing the component in operation.
When a port board is removed from the backplane, no alarm is logged for about 
11 minutes to allow for maintenance activity to proceed. After that, a minor 
on-board alarm is logged. If the port board is not administered, no alarm is 
logged.
!
WARNING:
This procedure can be destructive, resulting in a total or partial service 
outage.
!
WARNING:
Proceed only after consulting and understanding the applicable service 
documentation for the component.
!
WARNING:
Observe all Safety Precautions described above.
!
WARNING:
If the yellow LED on the circuit pack to be removed is lit, the circuit pack is 
active and services using it will be interrupted.
!
WARNING:
Follow special procedures for the circuit packs listed below.