Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-733
DUPINT (Duplication Interface Circuit Pack) 
9
active and standby SPE carriers. Then, if all DUPINT and DUP-CHL alarms are 
retired, a release of the standby SPE will allow memory shadowing to be turned 
back on (if no further alarms pertinent to memory shadowing are present) and 
refresh to complete. See STBY-SPE for more details as to how the turning on/off 
of shadowing is controlled.
Error Log Entries and Test to Clear Values
Notes:
a. Indicates either a failure during a reset of the Duplication Interface circuit 
pack, or a report that either or both of the HFAIL and STDONE bits are in 
the wrong state. These errors cause a MINOR alarm that does not affect 
memory shadowing. The Aux Data indicates which error occurred. 
Table 9-281.
Duplication Interface Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
1
1.
DUPINT alarms can be resolved only when the alarmed Duplication Interface circuit pack is in the
active SPE carrier.
On/Off 
Board
Test to Clear 
Value
0
0
Any
Any
Any
1
Control Register test (#865)
MAJOR
ON
test dupl l
257
Any
Mailbox Loop-around test (#866)
MAJOR
ON
test dupl l
513
Any
Local Loop-around test (#867)
MAJOR
ON
test dupl l
769
Any
Memory Shadowing Bounds Test 
(#868)
MAJOR
ON
test dupl l
2049 (a)
Any
Active DUPINT Reset Test (#870) 
Active DUPINT STDONE/ HFAIL Check 
Test (#979)
MINOR
ON
test dupl l
3073 (b)
2
None
MINOR
ON
test dupl l c
3329 (c)
Any
None
MAJOR
ON
test dupl l c
Aux 
Data
Cause of Error
None
The active DUPINT Reset Test failed because the reset was 
unsuccessful.
1
The STDONE bit is in the wrong state.
2
The HFAIL bit is in the wrong state.
3