Maintenance Object Repair Procedures 
9-746
E-DIG-STA (Emulated Digital Line) 
9
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence 
and only one test path in the test sequence. Once the test sequence is started, 
all tests in the test sequence are executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack 
and the hardware connected to those ports for lines administered as a digital 
station. These include stations with an emulated digital voice terminal and 
stations with an emulated digital voice terminal and a linked data module. 
Stand-alone data modules and data adaptors in stand-alone mode are not 
supported by the TN800 circuit pack. Circuit pack maintenance is covered by 
E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
 
(a) (b)
1.
Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ...); and pp is the two digit port 
number (01, 02, 03, ...).
Full Name of MO
E-DIG-STA
MINOR
test port UUCSSpp l
Emulated Digital St.
E-DIG-STA
WARNING
test port UUCSSpp sh
Emulated Digital St.
Table 9-288.
Digital Line Error Log Entries - E-DIG-STA
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port UUCSSpp sh r 1
18 (a)
0
busyout port UUCSSpp
WNG
OFF
rel port UUCSSpp
130 (b)
None
WNG
ON
test port UUCSSpp sh
257 (c)
40971
None
1537 (d)
40968
None
WNG
OFF
1793 (e)
Voice and Control Local 
Loop Test (#13)
MIN/ 
WNG
2
ON
test port UUCSSpp l r 3
2049 (f)
NPE Crosstalk Test (#9)
MIN/ 
WNG
2
ON
test port UUCSSpp l r 3