Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-755
EMG-XFER (Emergency Transfer) 
9
EMG-XFER (Emergency Transfer)
The Emergency Transfer maintenance object monitors the position of the 
Emergency Transfer switch(es) on the SYSAM circuit pack(s) in a PPN and the 
EPN Maintenance circuit packs in an EPN. It does not monitor whether or not the 
system is actually in Emergency Transfer.
Emergency Transfer (ET) provides the ability to connect designated analog 
phones to CO trunks when the switch cannot provide minimal phone service. 
Each cabinet (PPN and EPNs) has its own ET capability, and there is one 
EMG-XFER maintenance object for each cabinet or stack of single-carrier 
cabinets.
ET is controlled either automatically by the system, or manually, depending on 
the setting of the ET switches as described below.
Emergency Transfer Switches: EPNs and Simplex 
SPE
In a simplex SPE PPN cabinet, or in an EPN cabinet, if the ET switch is in the “on” 
position, ET is manually invoked and the system has no control of ET. This will 
generate a major alarm. In a simplex SPE PPN cabinet or in an EPN cabinet, if 
the ET switch is in the “off” position, ET cannot be invoked even if the system 
requests it. This will generate a warning alarm. Unless a technician is currently 
working on the cabinet, the switches should be left in the auto position, giving 
control of ET to the system.
Emergency Transfer Switches: Duplicated SPEs
On a system with duplicated SPE, the switches on both SYSAMs must be in the 
manual “on” position to manually invoke ET, generating a major alarm. If the 
switch on either SYSAM is in the manual “off” position, ET cannot be invoked, 
generating a warning alarm. Other settings give control to the system.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number as listed in the PORT field of the Alarm or Error Log.
Full Name of MO
EMG-XFER
MAJOR
test environment UU
Emergency Transfer
EMG-XFER
WARNING
test environment UU
Emergency Transfer