Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-18
LA85 Port Tester 
5
LA85 Port Tester
The LA85 port tester (Comcode 105138424) is recommended for troubleshooting 
all DEFINITY station troubles involving analog, DCP, MFET, MFAT, or BRI 
configuration. The port tester detects the presence of voltage from equipment 
ports and is degined to indicate the status of the wiring at the:
Wall field in the equipment room
Wall field in any intermediate closet
Wall jack at the station
Terminal and terminal station cord
Use the information in 
Table 5-2
 to isolate problems with the port tester.
Table 5-2. Port fault isolation using the LA85 Port Tester
To begin the isolation 
procedure at the
You may need this 
preliminary 
information or 
equipment And 
if
Then
Wall field in 
equipment room
Use display errors 
command
Off-board errors 
indicated
Verify wiring from switch to 
equipment room wall field.
Station (terminating 
end)
1. Unplug station cord 
from terminal and plug 
it into the “BRI” or 
“Other” jack on the 
tester, as applicable.
2. If the readings are OK, 
the terminal, handset, 
or handset cord may 
be faulty.
Station wall jack
1. Wrong or 
incorrect 
reading from 
the terminal end 
of the station 
cord (from Step 
1 above)
2. D8W line cord 
(Comcode 
103786761) 
used at station 
wall jack
1. If the reading from the 
jack is OK, then the 
terminal cord may be 
faulty.