Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-892
H-ADAPTR (MSS Host Adapter) 
9
2. Power down the SPE carrier by:
a. Remove the power plug from the left side of the carrier first.
b. Remove the second power plug from the right side of the carrier.
3. Replace the MSSNET circuit pack.
4. Power up the SPE carrier by:
a. Insert the power plug in the right side of the carrier first. 
b. After inserting the first power plug in the right insert the second 
power plug in the left side of the carrier.
5. Wait for the system to reboot.
c. Test the MSSNET circuit pack using the test mssnet long 
command.
d. Verify that the tape and disk are in service by issuing the status 
spe command.
6. If the SPE is duplicated:
b. After the standby SPE is powered up and fully refreshed, test the 
standby MSSNET circuit pack using the test mssnet long 
command.
Error Log Entries and Test to Clear Values
Table 9-340.
Host Adapter Error Log Entries 
Error 
Type
Aux 
Data
1
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1(a)
any
Host Adapter Hdwr 
Reset (#820)
MINOR
ON
test host-ad a|b
 l
18 (b)
0
Busyout host-ad
WARNING
OFF
rel host-ad a|b
257(c)
any
Host Adapter Diag 
(#823)
WARNING
ON
test host-ad a|b
 l r 3
513(d)
any
Host Adapter Diag 
(#823)
MINOR
ON
test host-ad a|b
 l r 3
529(e)
0
Host Adapter Reset 
(#893)
WARNING
ON
reset host-ad a|b
769(f)
any
Host Adapter 
Looparound (#824)
MINOR
OFF
test host-ad a|b
 sh r 2
1281(g)
any
Host Adapter Diag 
(#823)
MINOR
OFF
test host-ad a|b
 l r 2
Continued on next page