Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-937
ISDN-LNK (ISDN-PRI Signaling Link Port) 
9
A problem with the ISDN-LNK will have an effect on all of the associated 
B-channels since without it no call control information can be conveyed to the 
far-end switch or terminal adapter. Stable calls may remain operational, but no 
new calls can be made. The ISDN-LNK in turn depends on the TN464C/D UDS1 
Interface circuit pack it resides on and the packet bus which provides the link to 
the processor. If there are problems with the ISDN-LNK, also investigate the 
TN464C/D UDS1 Interface circuit pack (UDS1-BD) and the packet bus 
(PKT-BUS).
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. The D-channel is demand busied out. No calls can be made over this 
D-channel.
b. This Error Type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
ISDN-PRI Signaling Link Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port 
UUCSSpp
2
2.
pp is 24 for 24-channel interfaces and 16 for 32-channel interfaces.
18 (a)
0
busyout port 
UUCSSpp
2
WARNING
OFF
release port 
UUCSSpp
2
130 (b)
None
WARNING
ON
test port 
UUCSSpp
2
1537 (c)
46210
WARNING
OFF
1793 (d)
test board UUCSS l
3585 (e)
46222
MINOR
ON
3841 (f)
46211
3842 (g)
46223
3843 (h)
Signaling Port 
LAN Loopback 
test (#939)
test port 
UUCSSpp
2
 l