Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-985
MAINT (EPN Maintenance Circuit Pack)
9
Error Log Entries and Test to Clear Values
Notes:
a. A value of 0 indicates that PNC-A (and therefore, the Expansion Interface
circuit pack located on PNC-A) was active when this error occurred. A
value of 1 indicates that PNC-B (and therefore, the Expansion Interface
circuit pack located on PNC-B) was active when this error occurred. To
clear this problem, make sure the Active PNC is the same as that
indicated by the Aux Value.
value of 1 indicates that PNC-B (and therefore, the Expansion Interface
circuit pack located on PNC-B) was active when this error occurred. To
clear this problem, make sure the Active PNC is the same as that
indicated by the Aux Value.
b. Multiple values can appear in the Aux Data field. There will be other errors
in the log if there is a real problem. Use these other errors to troubleshoot
the problem.
the problem.
c. The serial link between the Expansion Interface circuit pack in the A
carrier and the EPN Maintenance circuit pack is defective.
Table 9-377.
EPN Maintenance Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test maintenance sh r 1
1(a)
0
1
1
EPN Maintenance Circuit
Pack Reset Test (#306)
Pack Reset Test (#306)
MINOR
ON
test maintenance l
513(a)
0
1
1
MGR I Channel Loop
Test (#228)
Test (#228)
MINOR
ON
test maintenance sh r 3
769(b)
Any
Sanity Handshake Test
(#106)
(#106)
1537(a)
0
1
1
Sanity Maze Test (#303)
MINOR
ON
test maintenance sh r 3
2561(a)
0
1
1
Sanity Handshake Test
(#106)
(#106)
MINOR
ON
test maintenance sh r 3
2817(a)
0(b)
1
1
Serial Channel Loop
Test (#229)
Test (#229)
MINOR
ON
test maintenance sh r 3
3329(c)
Any
Serial Link Test (#337)
MINOR/
WARNING
WARNING
2
2.
Major and Minor alarms may be downgraded to Warning alarms based on the value used in the
set options command.
set options command.
OFF
test maintenance sh r 3
3585(d)
Any
Serial Link Test (#337)
MINOR/
WARNING
WARNING
2
OFF
test maintenance sh r 3