Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-985
MAINT (EPN Maintenance Circuit Pack) 
9
Error Log Entries and Test to Clear Values
Notes:
a. A value of 0 indicates that PNC-A (and therefore, the Expansion Interface 
circuit pack located on PNC-A) was active when this error occurred. A 
value of 1 indicates that PNC-B (and therefore, the Expansion Interface 
circuit pack located on PNC-B) was active when this error occurred. To 
clear this problem, make sure the Active PNC is the same as that 
indicated by the Aux Value.
b. Multiple values can appear in the Aux Data field. There will be other errors 
in the log if there is a real problem. Use these other errors to troubleshoot 
the problem.
c. The serial link between the Expansion Interface circuit pack in the A 
carrier and the EPN Maintenance circuit pack is defective.
Table 9-377.
EPN Maintenance Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test maintenance sh r 1
1(a)
0
EPN Maintenance Circuit 
Pack Reset Test (#306)
MINOR
ON
test maintenance l
513(a)
0
MGR I Channel Loop 
Test (#228)
MINOR
ON
test maintenance sh r 3
769(b)
Any
Sanity Handshake Test 
(#106)
1537(a)
0
1
Sanity Maze Test (#303)
MINOR
ON
test maintenance sh r 3
2561(a)
0
Sanity Handshake Test 
(#106)
MINOR
ON
test maintenance sh r 3
2817(a)
0(b)
1
Serial Channel Loop 
Test (#229)
MINOR
ON
test maintenance sh r 3
3329(c)
Any
Serial Link Test (#337)
MINOR/ 
WARNING
2
2.
Major and Minor alarms may be downgraded to Warning alarms based on the value used in the 
set options command.
OFF
test maintenance sh r 3
3585(d)
Any
Serial Link Test (#337)
MINOR/ 
WARNING
2
OFF
test maintenance sh r 3