Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1000
MAPD-BD (MAPD Interface Circuit Pack TN802) 
9
PSTN fallback feature
The Public Switched Telephone Network (PSTN) fallback feature is available on 
the Internet trunk application software, which periodically pings the remote 
destinations that the software calls. When the far end returns a poor response 
time to the ping, DEFINITY’s ARS or AAR network routing patterns bypass those 
ports and direct the call to another port, typically on a PSTN trunk.
When the remote destinations show acceptable response times to subsequent 
pings, the corresponding ports are returned to “idle,” where they are available for 
service.
Cabinet configuration
Because of overheating, the TN802 circuit pack should not be placed directly 
above or below another MAPD circuit pack.
UPS protection
Because Windows NT is more vulnerable to damage from a power interruption 
than the DEFINITY ECS, uninterrupted power supply (UPS) protection is strongly 
recommended for systems using the TN802 circuit pack. 
2.
Select utility
In the IP Trunk Backup/Restore Utility dialog 
screen, click Files, Restore.
The IP Trunk Backup screen appears
3.
Select restore
In the IP Trunk Backup screen, click on the 
Restore button.
4.
Wait
Wait until the yellow Disk-In-Use LED (Note 5 in 
) light is out.
Table 9-386.
Restore TN802 administration data — Continued
Step
Description
Comments
Continued on next page