DEFINITY Administration
Is ATM PNC administered correctly?
1. Enter list atm pnc on the DEFINITY SAT. The cabinet, carrier and slot
positions of each administered TN230X board display as shown in
Figure
5-9
. Ensure that each board’s physical location matches the display.
Figure 5-9.
Screen output for list atm pnc command
Alternatively, use the list configuration UUC command (non-control
cabinets) to confirm the PPN and EPN board locations and correct
insertion.
cabinets) to confirm the PPN and EPN board locations and correct
insertion.
2. Enter status pnc at the DEFINITY SAT. This display tells you which
TN230X board is active in a duplicated system and how many alarms (if
any) of each severity level have been logged for the board.
any) of each severity level have been logged for the board.
shows the output from this command.