Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1017
MAPD-BD (MAPD Interface Circuit Pack TN802) 
9
Shutting down NT on the TN802
Before removing the TN802 circuit pack from the carrier, shut Windows NT
TM
 
down first by 
following either procedure described in 
Table 9-391
:
System Technician-Demanded Tests: Descriptions 
and Error Codes
Investigate tests in the order they are presented in 
By clearing error 
codes associated with the NPE Connection Audit Test, for example, you may also 
clear errors generated from other tests in the testing sequence.
Error Type 1538 
(hyperactivity) 
also present?
Then the switch:
Y
Takes the circuit pack out-of-service due to hyperactivity
N
Does not take the circuit pack out-of-service, but the 
circuit pack has generated 50% of the messages 
necessary to be considered hyperactive. This may be 
normal during heavy traffic periods.
Table 9-391.
Windows NT shutdown procedures
Step
Faceplate button
PC interface
1.
Push the recessed button on the front 
faceplate and hold it in.
Click on the “Start” button in the lower, lefthand 
corner.
2.
“M shut” flashes on the LCD display
Click on “Shut Down.”
3.
When shutdown is complete, “MSHUT 
#” displays (“#” is blinking).
Choose the “Shut down the computer?” radio 
button.
4.
Remove the circuit pack.
Click on “OK.”
5.
Wait for the message indicating that shutdown 
is complete.
6.
Remove the circuit pack.
Continued on next page