DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1057
MIS (Management Information System) 
9
MIS (Management Information 
System)
The Management Information System (MIS)/Call Management System (CMS) 
maintenance object is used only to monitor MIS busyouts during administration 
of MIS translations. There are no hardware failures associated with this MO.
The MIS/CMS is an adjunct processor that collects Automatic Call Distribution 
(ACD) data sent from the switch. In order to change MIS translations, a switch 
administrator must first enter a busyout mis command at the G3-MT. When the 
MIS is busied out, the switch will stop sending ACD data to the MIS, and a 
Warning alarm will be raised.
When the switch administrator is finished, a release mis command should be 
entered at the terminal. This will clear the Warning alarm and allow the switch to 
send ACD data to the MIS.
Error Log Entries and Test to Clear Values
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
MIS
WRN
release mis
Management Information System
Table 9-420.
Management Information System Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear 
Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
release mis
18
2
2.
When the busyout MIS command is issued, no data is sent to the MIS/CMS regardless of the 
link state. To allow data to be sent to MIS/CMS, a release mis command must be issued from 
the terminal.
0
busyout mis
WARNING
ON
release mis