Maintenance Object Repair Procedures 
9-1106
M/T-BD (Maintenance/Test Circuit Pack) 
9
c. A port processor on the circuit pack failed to initialize. Reset the circuit 
pack via busyout board UUCSSreset board UUCSS, and release 
board UUCSS
. if the problem does not go away, replace the circuit pack.
d. A Control Channel Protocol Error has occurred. This may be due to an 
on-board hardware failure detected by the circuit pack. Reset the circuit 
pack by executing busyout board UUCSS and reset board UUCSS 
commands. If there is a problem, it will be detected during initialization 
and will cause the circuit pack to lock up and appear insane to the 
system.
e. An extra TN771D circuit pack has been inserted into the port network.
f. An on-board hardware failure has been detected by the circuit pack. 
Reset the circuit pack via the busyout board UUCSSreset board 
UUCSS
, and release board UUCSS commands. If SAKI Sanity Test (#53) 
passes, the circuitry is healthy. If SAKI Sanity Test (#53) fails, replace the 
circuit pack.
g. This error is reported by the circuit pack when it detects a program logic 
error. While no action is required, this error may lead to errors of other 
types being reported against this circuit pack.
h. This error is reported by the circuit pack when it cannot update NPE 
memory and read it back. This error type can be ignored, but may lead to 
errors of other types being reported against this circuit pack.
i. Excessive number of messages have been received from the 
Maintenance/Test circuit pack. This may be due to a hardware problem on 
the circuit pack. The switch will take the board out of service and 
periodically put it back into service to see if the problem has disappeared. 
If the problem persists, replace the circuit pack.
j. This error is not service affecting. No action is required. This error is 
reported by the circuit pack when it receives a bad control channel 
message from the switch.
k. Error type 3999 indicates that the circuit pack sent a large number of 
control channel messages to the switch within a short period of time. If 
error type 1538 is also present, then the circuit pack was taken 
out-of-service due to hyperactivity. If error type 1538 is not present, then 
the circuit pack has not been taken out-of-service, but it has generated 
50% of the messages necessary to be considered hyperactive. This may 
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below whe
inspecting errors in the system. By clearing error codes associated with the