DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-45
ATM Tips 
5
The 
Result
 should be 
PASS
 for each test number. If the any of the 
tests fail, refer to 
 in 
Chapter 9
.
Possible Causes
1. The TN230X board is in a slot different from the DEFINITY administration.
2. The TN230X did not complete board insertion.
Physical Layer
Is there an optical signal between the TN230X and the A500?
1. Does the TN230X’s yellow LED flash 100ms on/100ms off, indicating a 
loss of signal on the fiber? Recall that the TN230X detects continuity 
problems with either the Transmit (bottom) or the Receive (top) fibers.
If there is loss of signal on the fiber, refer to th
 in this chapter.
2. Is the A500 port’s CD LED off, indicating a loss of signal on the fiber? Note 
that the A500 detects continuity problems only with the Receive 
(right-hand) fiber; the state of the Transmit (left-hand) fiber is not detected.
3. Enter show signaling summary on the A500 console. 
Figure 5-25
 shows 
the screen output.
Figure 5-25. A500: show signaling summary screen
Ensure that the fields have the values indicated below.
SAP State
Up
If it is 
PHY_DOWN
 or 
DOWN
, then there is probably a loss of signal 
on the port in question. This command detects a continuity 
problem only with the Receive (right-hand) fiber; it does not 
detect the state of the Transmit (left-hand) fiber.
State
The value of  may be 
UP
 or 
DOWN
, depending on the 
administration of the port. 
It may be necessary to 
re-administer the A500 port boards. Refer to the 
Cajun 
A500 Quick Reference for further information.
A500:show signaling summary
Port    loc VCI   SAP   IntType    Signaling   ILMI  SAP State     State
------  -------   ---   -------   -----------  ----  ------------  -----
A1.1      1       1     Network   UNI3.1       No    UP            UP
A1.2      2       2     Network   UNI3.1       No    UP            UP