Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1195
PGATE-BD (Packet Gateway Circuit Pack)
9
Error Log Entries and Test to Clear Values
Table 9-476.
PGATE-BD Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1 (a)
0
MINOR
ON
18 (b)
WARNING
OFF
release board UUCSS
23 (c)
0
WARNING
OFF
add pgate UUCSS
257
65535
Control Channel
Loop Test (#52)
Loop Test (#52)
MINOR
ON
test board UUCSS l r 20
257 (d)
513 (e)
4352 to
4357
4357
MINOR
ON
769 (f)
4358
1025(g)
4363
NPE Audit Test (#50)
1291 to
1296 (h)
1296 (h)
MINOR
ON
reset board UUCSS
1537(i)
ANY
MINOR
ON
1793
1794
1795 (j)
1794
1795 (j)
MINOR
ON
2049 (k)
Packet Interface
Test (#598)
Test (#598)
MINOR
ON
test board UUCSS l r 3
2305
2306 (l)
2306 (l)
2817
2819 (m)
2819 (m)
Congestion Query
Test (#600)
Test (#600)
MINOR
ON
test board UUCSS s r 3
3073 (n)
Link Status Test
(#601)
(#601)
MINOR
ON
test board UUCSS s
3329 (o)
MINOR
ON
reset board UUCSS
3568 (p)
3840 (q)
4096 to
4100
4100
3841
3843 (r)
3843 (r)
3842 (s)
3999 (t)
Any
None
Continued on next page