Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-53
ATM Tips 
5
ATM Call Control
Are ATM signaling connections being setup to A500 Call Control?
1. Enter show switch circuittable on the A500 console. 
Figure 5-33
 shows 
the screen output.
Figure 5-33. A500: show switch circuittable screen
Table 5-7. Observed Cause Codes
Cause 
Code
Definition
Observed Cause
3
No route to destination
The ATM addresses administered in the ATM switch 
(show signaling routes or show signaling esi) or in 
DEFINITY (display atm pnc) are incorrect.
31
Normal, unspecified
This is a normal return.
41
Temporary failure
This "try again later" Cause Code has been observed 
when the source of the problem is on another port (for 
example, a routing problem on another port that 
displays Cause Code 3).
47
Resources unavailable, 
unspecified
DEFINITY call volume is too high for the available 
resources in the ATM network.
63
Service or option unavailable, 
unspecified
DEFINITY call volume is too high for the available 
resources in the ATM network.
A500:show switch circuittable
 _______________________________________________________
|    Input     |    Output    |       Connection        |
| port vpi  vci| port vpi  vci| type class  parameters  |
|______________|______________|_________________________|
 
  A1.1   0    5  Self   0    1  pp   UBR    ppd on
  A1.1   0   32  A1.2   0   32  pp   VBRnrt pcr=5729  /scr=5729  /mbs=17187 
  A1.1   0   35  A1.2   0   35  pmp  CBR    pcr=173
 
  A1.2   0    5  Self   0    2  pp   UBR    ppd on
  A1.2   0   32  A1.1   0   32  pp   VBRnrt pcr=5729  /scr=5729  /mbs=17187 
  A1.2   0   34  A1.1   0   34  pmp  CBR    pcr=173
 
  Self   0    1  A1.1   0    5  pp   UBR    ppd on
  Self   0    2  A1.2   0    5  pp   UBR    ppd on
_________________________________________________________