Maintenance Object Repair Procedures 
9-1244
PKT-INT (Packet Interface Circuit Pack) 
9
PKT-INT (Packet Interface Circuit 
Pack)
The Packet Interface (PKT-INT) circuit pack (TN1655) serves as an interface 
between the Switch Processing Element (SPE) and the Packet bus in the 
Processor Port Network (see the figure in the following pages).
The PKT-INT supports links used for call setup of all ports located in Expansion 
Port Networks (EPNs). Therefore, if the PBX system is equipped with the 
Standard Reliability configuration (without duplicated SPEs), a failure of the 
Packet Interface circuit pack will prevent call origination and tear-down from 
telephones and trunks connected to EPNs. In addition to affecting telephone 
service, a failure of the Packet Interface circuit pack will affect service provided 
by the following circuit packs that connect to the Packet bus:
TN464C Universal DS1 circuit pack 
 ISDN PRI service
TN553 Packet Data Line circuit pack 
 System Port feature used for 
connectivity to features such as Call Detail Recording and dial-up 
administration.
TN556 ISDN-BRI Line circuit pack 
 ISDN BRI service
TN577 Packet Gateway circuit pack 
 BX.25 links used for services 
requiring BX.25 links such as AUDIX and Distributed Communications 
Systems
If the PBX system is equipped with the High Reliability or Critical Reliability option 
(i.e. with duplicated SPEs), and if a failure of the Packet Interface circuit pack on 
the active SPE causes a MAJOR alarm, a SPE interchange will occur if the state 
of health of the standby SPE is high enough to permit an interchange. A MAJOR 
alarm caused by a failure of a Packet Interface circuit pack on the standby SPE 
will drop the state of health of the standby SPE which prevents any attempt to 
interchange SPEs.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
1.
C is the carrier location (a or b), S is the position number of the Packet Interface circuit pack (1, 2,
or 3). The carrier location is required only for duplicated SPEs.
Full Name of MO
PKT-INT
MAJOR
2
2.
If a spontaneous interchange has occurred (as indicated by STBY-SPE error type 103 or the
display initcauses screen), and handshake is down, (check with status spe), replace the alarmed
circuit pack on the standby SPE. If handshake is up, execute a test long clear of the alarmed circuit
pack and follow recommended procedures.
reset packet-interface CS
Packet Interface Circuit Pack
PKT-INT
MINOR
test packet-interface CS l
Packet Interface Circuit Pack
PKT-INT
WARNING
test packet-interface CS l
Packet Interface Circuit Pack