DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1286
PMS-LINK (Property Management System Link) 
9
m. The link was taken down by the switch because the threshold for 
application protocol violations has been exceeded by the PMS. The 
protocol never started and messages were received and/or messages 
were received in a state in which they were not expected. (Refer to Error 
Type 2817 for recommended strategy.)
n. Link was taken down by the switch because the threshold for link protocol 
violations has been exceeded by the PMS. PMS is sending ‘‘garbage’’ to 
the switch.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Link Retry Test, for example, you may also clear 
errors generated from other tests in the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external PMS 
device. If the link has been disconnected already, then this test just returns 
‘‘PASS.’’ All resources allocated for a PMS Link are released after this test. 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Link Tear Down Test (#213)
X
D
Link Retry Test (#215)
X
X
ND