Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1302
PNC-DUP (PNC Duplication) 
9
3. Follow the appropriate diagnostic and repair procedures for the alarmed 
PNC components just as with a simplex PNC. Both the alarm and error 
logs should be examined to isolate the fault.
4. Verify that the related PNC SOH is restored to all zeros.
5. Release the standby PNC for busy-out.
Refresh and Unrefresh of the Standby PNC
In a fully functional PNC with healthy standby and active sides, the standby PNC 
has a complete set of call connections corresponding to those in the active PNC. 
If, however, the state of health of the standby PNC degrades, a selective 
unrefresh of those connections which utilize the faulted component(s) is 
performed. If the health of the standby PNC improves, a selective refresh of 
connections on the affected route is performed. so that call setup is consistent 
between the active PNC and the healthy parts of the standby PNC.
The 
Standby Refreshed?
 field on the status pnc screen does 
not refer to the 
selective type of refresh. It refers only to a global refresh which is performed 
when:
The system is initialized and PNC duplication is enabled.
There has been a spontaneous PNC interchange.
The standby PNC has been released from busy-out.
A system reset of level 2 or higher has taken place.
The refreshed field may display 
yes
 when in fact the standby is partially 
unrefreshed. An interchange into an incompletely refreshed standby will result in 
dropped calls. This can happen when a more severe fault occurs on the active 
PNC, or when set pnc interchange is used with the override option.
PNC Interchanges
PNC spontaneous interchanges occur when PNC duplication software 
determines that the SOH of the standby PNC is better than that of the active PNC. 
PNC-DUP executes a spontaneous interchange only when a message from a 
PNC component maintenance object sends a message indicating that either a 
fault has occurred on the active PNC, or a fault has been resolved on the standby 
PNC such that the state of health of the active PNC is now lower than that of the 
standby.
This message will usually indicate the type and location of the failed connectivity 
component. A corresponding major or minor alarm is logged by the reporting 
MO, stimulating an alarm report.