Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1306
PNC-DUP (PNC Duplication) 
9
Error Log Entries
Whenever a PNC interchange takes place, an error is logged against PNC-DUP 
with a code that conveys information about the cause of the interchange and 
which PNC became active. There are no alarms associated with PNC-DUP 
errors, but there should be an alarm against the PNC component that drove the 
interchange. There are no PNC-DUP test sequences, but status pnc will provide 
information regarding the status of the PNCs. The information given in the 
following tables will help to identify areas of the Alarm Log to be investigated to 
find the source the problem. .
Notes:
a. An error took place in generating the error code.
Error Code
Aux 
Data
Error Code
Aux 
Data
00000 (a)
None
20200 to 20221 (r)
1
10000 to 10021 (b)
1
1.
The Aux Data indicates which PNC became active after the PNC interchange: ‘‘0’’
denotes PNC-A; ‘‘1’’ denotes PNC-B.
20300 to 20321 (s)
1
10100 to 10121 (c)
1
20400 to 20421 (t)
1
10200 to 10221 (d)
1
20601 to 20627 (u)
1
10300 to 10321 (e)
1
20701 to 20727 (v)
1
10400 to 10421 (f)
1
21000 to 21021 (w)
1
10601 to 10627 (g)
1
21100 to 21121 (x)
1
10701 to 10727 (h)
1
21200 to 21221 (y)
1
11000 to 11021 (i)
1
21300 to 21321 (z)
1
11100 to 11121 (j)
1
21400 to 21421 (aa)
1
11200 to 11221 (k)
1
21601 to 21627 (ab)
1
11300 to 11321 (l)
1
21701 to 21727 (ac)
1
11400 to 11421 (m)
1
51000 (ad)
1
11601 to 11627 (n)
1
52000 (ae)
1
11701 to 11727 (o)
1
53000 (af)
1
20000 to 20021 (p)
1
60801 (ag)
1
20100 to 20121 (q)
1
60800 (ah)
1
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
18
None
busy PNC-DUP
WARNING
ON
release pnc-dup