Alarms, Errors, and Troubleshooting 
5-66
Troubleshooting ISDN-PRI Problems 
5
When a downgrade does occur, information on the Status Conference form 
indicates the success or failure of the 64kbps-endpoints that are participants to 
properly rate adapt to 56kbps. As a general indication that the conference has 
rate adapted, the 
Conference Transfer Rate
 and 
Effective Transfer 
Rate
 fields show initial and current transfer rates, respectively. For each 64-kbps 
endpoint the column that indicates 
Rate Adapt
 shows an 
n
 if the endpoint did 
not follow the procedures as specified by the H.221. If an endpoint shows 
y
, it did 
successfully rate adapt. If an endpoint shows 
c
, it joined the conference at 
56kbps.
Once the conference rate adapts, the endpoints that do not properly follow suit, 
will become audio-only endpoints. A conference will not rate adapt from 56 kbps 
back to 64 kbps until all endpoints disconnect from the conference and it idles.
The PictureTel 1000 Release 1.1C, PictureTel 6.01 software, and the Vistium 2.0 
software successfully rate adapt with the MCU. External rate adaptation 
techniques used by VTEL and CLI are known to cause problems with the 
endpoint when used with this feature.
Endpoint or I-MUX in Loopback Mode
Some endpoints have a loopback enable feature. This makes DEFINITY MMCH 
data loopback at the MMCH when a connection is in progress. The loopback can 
be enabled prior to or during a connection.
The MMCH does not detect the loop and continues to VAS. In most scenarios, 
the switch occurs, but within a few seconds, the broadcaster’s return video 
becomes its own image. Once the broadcaster stops speaking, the system 
“false” switches to an apparently random port that was not speaking.
Troubleshooting ISDN-PRI Problems
The following flow chart defines a layered approach when troubleshooting 
ISDN-PRI problems. Since a problem at a lower layer affects upper layers, layers 
are investigated from low to high. In the flowchart, the DS1 facility is layer 1, the 
ISDN-PRI D-channel is layer 2, and the ISDN trunks are layer 3. Transient 
problems are diagnosed on Page 2 of the flowchart. For problems with PRI 
endpoints (wideband), see the following section.